top of page

VCI/VMI Series

Direct Heat CO2
Tri-gas Incubator



Direct Heat CO2Tri-gas Incubator

New Face Design: Renovated front door with an ergonomic handle, accompanied with a smooth polished stainless steel interior, and touch screen monitor with high speed processing.Best Suited for cell culture: Much like its predecessor (the CPI series), the VCI/VMI grants an ideal environment for cell culture. Further advancements have been made to simplify user maintenance, while allowing safe & easy access to the samples inside.




Dry Heat Sterilization(160C)

Standard Equipped

Considering the effects of the various techniques of sterilization on the cells, Dry Heat Sterilization is the most ideal method used for incubators.




Easily Accessible



Cell Monitoring System (Optional)

Users can connect to an optional, built in, cell monitoring system and observe the culture process on the front door panel display.


Compatibility with cell monitor

● Compatibility with cell monitor recording output via USB.

● Easy to connect and disconnect via single touch connector.



【Applications】

Live/ Timelapse observation

①Live: Allows observation without opening/closing the chamber. Ideal for stress sensitive cells.②Timelapse: Allows periodical recording of cell reproduction curve. Tracing patterns in segments of cell formation and density.



【Applications】

Confluency

③Automated evaluation and recording of cell density. Confirmation of passage timing: human evaluation assisted with device evaluation allows confluency evaluation without interference to chamber granting a unified approach and setting to passage timing.



【Applications】

Cell Quality Control

④Continuous analogy is visually graphed and recorded as above. Cell Quality Control: Comparative analysis between previous and present trial. Evaluation of efficiency and error can be easily viewed, quickly noticed, and corrected if needed.


Movie




Specification

VCI-165P120LE/230LE

Exterior dimensions

620 mm x 740 mm x 850 mm/ 24.4 in. x 29.1 in. x 33.5 in. (W x D x H)


(Projections not included) 

Interior dimensions

W481 mm × D531 mm × H640 mm

Capacity

Approx. 163 L

Outer facing

Electrogalvanized steel sheet (Baked powder coating)

Inner facing

Stainless steel plate (SUS304, SUS430)

Shelf board

W455 mm × D468 mm × H23 mm 4 boards in the standard configuration (10 boards max.)

Access board

φ29 mm (Standard configuration)

Temperature control method

Digital PID control

Temperature control range

Room temperature plus 5°C to 50°C (0.1°C steps)

Temperature control accuracy

±0.1°C

Temperature uniformity

±0.3°C

Temperature control range


for dry-heat sterilization

50°C to 160°C (1°C steps)

Temperature uniformity regarding


dry-heat sterilization

±3°C

Sterilization temperature setting time

0.1 to 10.0 hours

CO2 sensor

NDIR sensor

CO2 concentration control range

0.0%~20.0%

CO2 concentration control accuracy

±0.1%

O2 sensor

-

O2 concentration control range

-

O2 concentration control accuracy

-

Humidifying method, humidity

Natural evaporation method (Vat water filling), 95% ±4% RH

Safety devices

Over-temperature protection, over-temperature alarm, CO2 alarm, O2 alarm,


other various alarms

Product weight

90 kg

Power supply

Single-phase 110-120V AC, 50/60 Hz, or Single-phase 220-240V AC 50/60 Hz, 7.5 A

Power consumption

750 W(max.)

Power consumption (Watt-hour)

75 Wh (at room temperature 25°C, set temperature 37.0°C, stable operation)

Working temperature range

10°C ~ 30°C

Working humidity range

30% ~ 80%RH

Storage temperature range

-20°C ~ 50°C

Storage humidity range

20% ~ 80%RH

Options

Cell monitor


Analogue output


Alarm contact output


Gas guard


Door lock


Cart


Vertical joint bracket


Dust collection filter

VMI-165P120LE/230LE

Exterior dimensions

620 mm x 740 mm x 850 mm/ 24.4 in. x 29.1 in. x 33.5 in. (W x D x H)


(Projections not included) 

Interior dimensions

W481 mm × D531 mm × H640 mm

Capacity

Approx. 163 L

Outer facing

Electrogalvanized steel sheet (Baked powder coating)

Inner facing

Stainless steel plate (SUS304, SUS430)

Shelf board

W455 mm × D468 mm × H23 mm 4 boards in the standard configuration (10 boards max.)

Access board

φ29 mm (Standard configuration)

Temperature control method

Digital PID control

Temperature control range

Room temperature plus 5°C to 50°C (0.1°C steps)

Temperature control accuracy

±0.1°C

Temperature uniformity

±0.3°C

Temperature control range


for dry-heat sterilization

50°C to 160°C (1°C steps)

Temperature uniformity regarding


dry-heat sterilization

±3°C

Sterilization temperature setting time

0.1 to 10.0 hours

CO2 sensor

NDIR sensor

CO2 concentration control range

0.0%~20.0%

CO2 concentration control accuracy

±0.1%

O2 sensor

Galvanic battery-type sensor

O2 concentration control range

2.0%~80.0%

O2 concentration control accuracy

±0.5%

Humidifying method, humidity

Natural evaporation method (Vat water filling), 95% ±4% RH

Safety devices

Over-temperature protection, over-temperature alarm, CO2 alarm, O2 alarm,


other various alarms

Product weight

90 kg

Power supply

Single-phase 110-120V AC, 50/60 Hz, or Single-phase 220-240V AC 50/60 Hz, 7.5 A

Power consumption

750 W(max.)

Power consumption (Watt-hour)

75 Wh (at room temperature 25°C, set temperature 37.0°C, stable operation)

Working temperature range

10°C ~ 30°C

Working humidity range

30% ~ 80%RH

Storage temperature range

-20°C ~ 50°C

Storage humidity range

20% ~ 80%RH

Options

Cell monitor


Analogue output


Alarm contact output


Gas guard


Door lock


Cart


Vertical joint bracket


Dust collection filter


Çamlıca Mahallesi Anadolu Bulvarı No: 20 Timko AA2  06200 Yenimahalle / Ankara – TURKEY

Teknopol İstanbul, Ahmet Yesevi Mahallesi Kerem Sokak  No: 9/1/20  34903 Pendik / İstanbul -TURKEY

+90 312 387 37 67

  • Instagram
  • Facebook
  • Twitter
  • LinkedIn
  • YouTube

© 2025 Optimas. All Rights Reserved. Please read the Legal Notice for further details.