top of page

CCM-iBIS Time-lapse

Making “Time-lapse” Affordable & Easy
As a pioneer of time-lapse incubation systems (since 2005), ASTEC proudly introduces the all new cell monitoring system for embryo culture known as the “CCM-iBIS”. Utilizing a robust built-in gas mixing system, we have successfully reduced the gas consumption and made our unit to be the most cost-effective time-lapse unit available in the market today.





Specification

Main body

External dimensions

(W)382mm x (D)590mm x (H)219mm* (Projections excluded)

Number of settable dishes

9 (25-Well EmbryoGrid)

Inside-chamber dimensions

62 mm (W) x 65 mm (D) x 17 mm (H) Capacity: Approx. 69 ml

Humidification method

Non humidification

Power supply

110V-120 VAC 50/60Hz 3A or 220-240 VAC 50/60Hz 1.5A (Voltage fluctuation : within ±10%)

Weight of the main body

Approx. 30kg

Temperature control

External dimensions

(W)382mm x (D)590mm x (H)219mm* (Projections excluded)

Temperature control method

Digital PID method, independent control of each incubation chamber

Operational temperature range

24ºC to 28ºC

Temperature control range

36ºC to 38ºC

Temperature fluctuation range

±0.1ºC (Room temperature: 26ºC)

Temperature distribution

±0.1ºC (Room temperature: 26ºC)

Main heater

Silicon rubber heater

Gasspecifications

CO2 sensor

Infrared CO2 sensor

CO2 control method

Duty control

CO2 control range

0 to 20.0%

CO2 fluctuation range

±0.1%

O2 sensor

Ceramic O2 sensor

O2 control method

Duty control

O2 control range

2.0 to 18.0%

O2 fluctuation range

±0.5%

XY stage

Shift range

±105 mm (x-axis), ±140 mm (y-axis)

Resolution

1μm/step

Maximum speed

40mm/sec

Repetitive-positioning accuracy

Within ±0.5 μm

Z stage

Shift range

±5mm

Resolution

1 μm/step (Half)

Maximum speed

10mm/sec

Repetitive-positioning accuracy

Within ±0.2 μm

Optical system

Camera

1.3-million pixel CCD camera, 4.86 mm x 3.62 mm imaging size

Objective lens

Lens (10 x) for biological microscopes

Light source for illumination

Red LED (Peak wavelength: 623 nm)

Image

Image save formata

JPEG format

Image save method

NAS (Mirroring function-equipped, 6TB x 2)s

External output

Analog output

Temperature (9 incubation chambers), CO2 concentration, O2 concentration

Contact output

Close when an alarm is generated; close when the power is turned Off


opt

Çamlıca Mahallesi Anadolu Bulvarı No: 20 Timko AA2  06200 Yenimahalle / Ankara – TURKEY

Teknopol İstanbul, Ahmet Yesevi Mahallesi Kerem Sokak  No: 9/1/20  34903 Pendik / İstanbul -TURKEY

+90 312 387 37 67

  • Instagram
  • Facebook
  • Twitter
  • LinkedIn
  • YouTube

© 2025 Optimas. All Rights Reserved. Please read the Legal Notice for further details.

Bu siteyi kullanarak, çerezleri kullanmamızı kabul etmiş olursunuz.

bottom of page